ANYLOAD A2P & A2P-D2 Load Cell Amplifier
This ANYLOAD A2P or A2P-D2 amplifiers provide signal conditioning for load cells and force transducers. Their versatile design enables direct connection of 1 – 2 load cells. They also can drive up to 8 load cells through the use of a junction box. See the description tab below for model differences.
For a quick comparison of this product to our other amplifier products, see our Load Cell Amplifier Comparison Table in our Knowledge Base.
Title | Quantity | Price |
---|---|---|
1-9 | 1 - 9 | 0% $394.00 |
10-24 | 10 - 24 | 5% $374.30 |
25-49 | 25 - 49 | 8% $362.48 |
50-99 | 50 - 99 | 11% $350.66 |
100+ | 100 + | 15% $334.90 |
ANYLOAD A2P & A2P-D2 Load Cell Amplifier
The ANYLOAD A2P & A2P-D2 load cell amplifiers provide load cell & transducer signal conditioning. They can be installed on a standard rail channel & drive up to 2 x 350Ω load cells directly. With a junction box, they can drive 4×350Ω or 8×700Ω (or 8×350Ω for -D2 option) load cells.
- AC & DC powered
- Housed in PVC enclosure
- Individual adjustable resistors
- Contains 2 through holes for easy installation
- Compliance: Conformité Européenne (CE) – Electromagnetic Compatibility Directive
- The A2P has 12V excitation voltage and AC power supply option
- The A2P-D2 has two excitation voltages, 5VDC or 12VDC
- The A2P-D2B is the same as the A2P-D2 but adds Balluff IO-Link compatibility
Available Options: A2P-D2B
Previous models may be available. Please contact us with any product-related questions.
Tacuna Systems Commitment
We strive to help our diverse customer base achieve their desired outcomes. As a small business, we take great pride in providing free consultation for product design & prototyping to ensure our valued clients have the right equipment to be successful. Our engineering specialists have extensive R&D experience in strain gauge load cell technology, and we are well-known for our in-house designed customizable signal conditioners and amplifiers.
Specifications
ANYLOAD A2P-D2 Load Cell Amplifier Specifications
Specification | A2P | A2P-D2* |
Offset Range | ±2V | ±2V |
Load Cell Type | All strain gauge types | All strain gauge types |
Power Supply | 24VDC or 95-250VAC | 24VDC ± 20% |
Input Range | 0-30mV | 0±36mV |
Output Signal (Voltage) | 0-10V | 0±10V |
Output Signal (Current) | 4-20mA | 4-20mA |
Excitation Voltage to Load Cell | 12V | 5V or 12V |
Operating Temperature Range | -10 to 50°C or 14 to 122°F | -10 to 50°C or 14 to 122°F |
Enclosure Material | PVC casting | PVC casting |
Capacity | Up to 2×350Ω directly connected or 4×350Ω or 8×700Ω through a junction box |
Up to 2×350Ω directly connected or 4×350Ω or 8×700Ω or 8×350Ω through a junction box |
IP Rating | IP40 | IP40 |
Installation | Standard rail channel | Standard rail channel |
Tare Limit | Shall not exceed 30% of full load | Shall not exceed 30% of full load |
*A2P-D2B is compatible with Balluff IO-Link
Technical Documents
A2P Datasheet A2P-D2 Datasheet |
|
A2P Manual A2P-D2 Manual |
|
CE Certificate – Electromagnetic Compatibility Directive |
Only logged in customers who have purchased this product may leave a review.