• a photo of a load cell amplifier

ANYLOAD A2P & A2P-D2 Load Cell Amplifier

 

This ANYLOAD A2P or A2P-D2 amplifiers provide signal conditioning for load cells and force transducers. Their versatile design enables direct connection of 1 – 2 load cells. They also can drive up to 8 load cells through the use of a junction box. See the description tab below for model differences.

For a quick comparison of this product to our other amplifier products, see our Load Cell Amplifier Comparison Table in our Knowledge Base.

Quantity Price
1 - 9 $394.00
10 - 24 $374.30
25 - 49 $362.48
50 - 99 $350.66
100 + $334.90
Tacuna Systems Price Match Guarantee

ANYLOAD A2P & A2P-D2 Load Cell Amplifier

The ANYLOAD A2P & A2P-D2 load cell amplifiers provide load cell & transducer signal conditioning. They can be installed on a standard rail channel & drive up to 2 x 350Ω load cells directly. With a junction box, they can drive 4×350Ω or 8×700Ω (or 8×350Ω for -D2 option) load cells.

  • AC & DC powered
  • Housed in PVC enclosure
  • Individual adjustable resistors
  • Contains 2 through holes for easy installation
  • Compliance: Conformité Européenne (CE) – Electromagnetic Compatibility Directive
  • The A2P has 12V excitation voltage and AC power supply option
  • The A2P-D2 has two excitation voltages, 5VDC or 12VDC
  • The A2P-D2B is the same as the A2P-D2 but adds Balluff IO-Link compatibility

Available Options:  A2P-D2B
Previous models may be available. Please contact us with any product-related questions.

Tacuna Systems Commitment

We strive to help our diverse customer base achieve their desired outcomes. As a small business, we take great pride in providing free consultation for product design & prototyping to ensure our valued clients have the right equipment to be successful. Our engineering specialists have extensive R&D experience in strain gauge load cell technology, and we are well-known for our in-house designed customizable signal conditioners and amplifiers.

Specifications

ANYLOAD A2P-D2 Load Cell Amplifier Specifications

Specification A2P A2P-D2*
Offset Range ±2V ±2V
Load Cell Type All strain gauge types All strain gauge types
Power Supply 24VDC or 95-250VAC 24VDC ± 20%
Input Range 0-30mV 0±36mV
Output Signal (Voltage) 0-10V 0±10V
Output Signal (Current) 4-20mA 4-20mA
Excitation Voltage to Load Cell 12V 5V or 12V
Operating Temperature Range -10 to 50°C or 14 to 122°F -10 to 50°C or 14 to 122°F
Enclosure Material PVC casting PVC casting
Capacity Up to 2×350Ω directly connected
or
4×350Ω or 8×700Ω through a junction box
Up to 2×350Ω directly connected
or
4×350Ω or 8×700Ω or 8×350Ω through a junction box
IP Rating IP40 IP40
Installation Standard rail channel Standard rail channel
Tare Limit Shall not exceed 30% of full load Shall not exceed 30% of full load

*A2P-D2B is compatible with Balluff IO-Link

Technical Documents

A2P Datasheet
A2P-D2 Datasheet
A2P Manual
A2P-D2 Manual
CE Certificate – Electromagnetic Compatibility Directive