ANYLOAD 363RS Compression Load Cell
- Stainless steel material
- Mounting hardware included
- Full Scale Output: 2mV/V ± 0.1%
- Safe Overload: 150%
- Breaking Overload: 300%
- Rated Capacities: 250kg, 500kg, 1t, 2t, 3.5t, 5t, 10t, 13t, 28t, 60t
- IP Rating: IP68
- CE and RoHS certified
Available options: 363RS-60kg, 363RS-250kg, 363RS-500kg, 363RS-1000kg, 363RS-2000kg, 363RS-3500kg, 363RS-5000kg
Please contact us with any product interfacing inquiries.
Compression Load Cell Interchangeable Cross Reference
Manufacturer | Model |
Metter-Toledo | RLC |
Vishay Revere Transducers | RLC |
Tacuna System’s Commitment
We strive to serve our diverse customer base across all industries, enabling them with the proper tools they need to be successful. As a small business, we take great pride in providing free consultation for product design & prototyping to all our valued customers. Our engineering specialists also have extensive R&D experience in strain gauge load cell technology, as we are well-known for our in-house designed signal conditioners and amplifiers, that can be customized.
363RS Stainless Steel Compression Load Cell Specifications
Rated Capacity | 250kg, 500kg, 1t, 2t, 3.5t, 5t, 10t, 13t, 28t, 60t |
Full Scale Output | 2mV/V ± 0.1% |
Zero Balance | ± 0.05mV/V |
Non-linearity | < ± 0.023% |
Repeatability | < ± 0.023% |
Hysteresis Error | < ± 0.023% |
Creep in 30 minutes | < ± 0.030% |
Input Resistance | 1500Ω ± 50Ω |
Output Resistance | 1400Ω ± 10Ω |
Recommended Excitation | 10V (15V Maximum) |
Insulation Resistance | > 2GΩ (50V DC) |
Temperature Effect on Sensitivity | < ±0.0023% of Cn/k |
Temperature Effect on Zero Balance | < ± 0.0120% of Cn/k |
Compensated Temperature Range | –10°C to 50°C/14°F to 122°F |
Service Temperature Range | –30°C to 70°C/-20°F to 160°F |
Storage Temperature Range | -50°C to 85°C/-58°F to 185°F |
Safe Overload | 150% of full scale |
Breaking Overload | 300% of full scale |
Seal Type | Welded seal |
IP Rating | IP68 |