Select Page

ANYLOAD 563YHMS Alloy Steel Single-Ended Beam Load Cell

The 563YHMS Alloy Steel Single-Ended Beam Load Cell delivers reliable and accurate weighing for a broad variety of industrial and technical weighing applications.

Other capacities and configurations available—please contact us with any questions.

$470.40$1,132.80

Clear
SKU: AL-563YHMS Category:
Weight7 lbs
Capacity

, ,

Key Features

  • Alloy steel material
  • Rated Capacities: 1Klb, 2.5Klb, 4Klb, 5Klb, 10Klb, 20Klb
  • Full Scale Output: 2mV/V ± 0.07%
  • Safe Overload: 150%
  • Breaking Overload: 300%
  • IP Rating: IP67
  • CE, RoHS and Ex certified
  • Measurement Ukraine certified

Available options: 563YHMS-5000lb, 563YHMS-10000lb, 563YHMS-20000lb

Please contact us with any product interfacing inquiries.

 

Interchangeable Cross Reference
ManufacturerModelInfo
Rice LakeRLSB2MLWConstructed with stainless steel and designed for capacities 1Klb-20Klb
Rice LakeRLSB2LConstructed with alloy steel and designed for capacities 35Klb-45Klb
Mettler-ToledoML4311-4449 
563YHMS Alloy Steel Single-Ended Beam Load Cell Specifications
Rated Capacity1Klb, 2.5Klb, 4Klb, 5Klb, 10Klb, 20Klb
Full Scale Output2mV/V ± 0.07%
Zero Balance± 0.02mV/V
Non-linearity< ± 0.017%
Repeatability< ± 0.017%
Hysteresis Error< ± 0.017%
Creep in 30 minutes< ± 0.023%
Input Resistance350Ω ± 7Ω
Output Resistance350Ω ± 3Ω
Recommended Excitation10V (15V Maximum)
Insulation Resistance> 2GΩ (50V DC)
Temperature Effect on Sensitivity< ± 0.0012% of Cn/k
Temperature Effect on Zero Balance< ± 0.0040% of Cn/k
Nominal Temperature Range10°C to 50°C/14°F to 122°F
Service Temperature Range30°C to 70°C/-20°F to 160°F
Storage Temperature Range-50°C to 85°C/-58°F to 185°F
Safe Overload150% of full scale
Breaking Overload300% of full scale
Seal TypeEnvironmentally sealed
IP RatingIP67