ANYLOAD 815TS Digital Weight Indicator

 

The ANYLOAD 815TS LED weight indicator is a high-accuracy, multi-function device designed for industrial, food, and agricultural applications. It supports up to eight 350Ω or sixteen 700Ω load cells through a junction box. The 815TS features a password-protected calibration menu, audit trail function, and advanced analog, digital, and average filtering. Encased in a heavy-duty SS304 stainless steel wash-down enclosure, it is IP66-rated for durability and reliability in harsh environments.

$710.00

Quantity Price
1 - 9 $710.00
10 - 24 $674.50
25 - 49 $653.20
50 - 99 $631.90
100 + $603.50
Tacuna Systems Price Match Guarantee

ANYLOAD 815TS Digital Weight Indicator Features

The ANYLOAD 815TS LED weight indicator is a high-accuracy, multi-function industrial weighing device designed for reliability in various applications. It supports up to eight 350Ω or sixteen 700Ω load cells through a junction box, ensuring precise measurements. The 815TS features a password-protected calibration menu and electronic sealing via an audit trail function, enhancing security and traceability. Advanced analog, digital, and average filtering capabilities further improve measurement accuracy. Encased in a durable SS304 stainless steel wash-down enclosure, the 815TS is IP66-rated, making it ideal for food, agricultural, and industrial environments. This robust design ensures the indicator performs well even in harsh conditions.

  • 0.8”, 6 digits, 7 segments, LED display
  • Indication of four units of measurements: kg, lb, oz, and g
  • Indication of gross, net, and tare
  • Indication of stability and center of zero
  • Easy wiring screw terminals
  • Weight, peak, set point, and piece counting
  • Password-protected calibration menu
  • Physical and electronic sealing via audit trail function
  • Two set point output relays
  • Advanced analog, digital, and average filtering
  • Two independent RS232 serial communication ports
  • One independent RS485 serial communication port
  • Weatherproof stainless steel enclosure, NEMA4X / IP66
  • Breather vent to avoid condensation inside
  • Built-in clock
  • Front panel calibration
  • Power Supply: UL-approved internal 110VAC to 220VAC, 50-60Hz

Available Option: 815TS-B-21E

This indicator is compatible with all brands and capacities of load cells in Tacuna Systems’ catalog. Note that it must be calibrated to the paired load cell. Purchasers can perform this calibration with a known load (2/3 of full capacity). Alternatively, Tacuna Systems can pair the indicator with the load cell–select our Load Cell Calibration Service with purchase.

Please contact us with any product inquiries.

Functions

  • Auto Zero Scale
  • Auto Zero Tracking
  • Normal Weighing
  • Peak
  • Counting
  • Zero Scale
  • Tare
  • Alarm when load exceeds the maximum load capacity of the scale or load cell
  • Password protected calibration menu and electronic sealing via audit trail function
  • RS-232 and RS-485
  • Two setpoint relays
  • Print Interface (PS805)
  • Advanced analogue, digital, and average filtering

Specifications

ANYLOAD 815TS General Specifications

Power Supply UL approved internal, 100VAC to 240 VAC, 50-60Hz
Power Consumption 120VAC @ 0.1A/12VDC @ 0.5A (10W AC/5W DC) typical
Excitation Voltage 5V DC ± 5%
Number of Load Cells Up to 8×350Ω; 16×700Ω
Input Range Up to 19mV/4mV/V
Sample Rate 80 Samples/Second
Resolution 1,000,000 internal count, with 24bits resolution
Division Legal for trade 10,000d/20,000d
Tare Range 100% Full-Scale NTEP/MC/ OIML
Communicate Interface 2 x RS-232C, 1 x RS-485
Output 2 x form C Relays
Working Humidity 20% RH to 90% RH
Working Temperature -10°C to 50°C / 15°F to 120°F
Dimensions (WxHxD) 9.1″ x 7.4″ x 3.0″(231 x 188 x 76mm) base included

Technical Documents

815TS Datasheet
815TS Manual

Approvals

NTEP Certificate of Conformance
Measurement Canada Approval
CE Certificate of Conformity – Electromagnetic Compatibility Directive
CE Certificate of Conformity – Low Voltage Directive

Tutorial Video

815TS Calibration Settings Video

FAQ

Question Answer
1. Where can I find the manual? The manual can be found on the ANYLOAD website. Under each product Picture and Description, there will be the MANUAL tab with the corresponding user manual.
2. What is the maximum capacity we can use for this indicator? The capacity can be set in F1.7. The maximum capacity is 999999 in the unit that the device is set to. The unit can be changed in F1.3.
3. What communication interfaces does the 815-series have? There are two communication ports available as RS232-1 and RS232-2. The baud rate and data bit setting can be accessed in F5.0-F5.9.
4. How does this calibrate and where can I find the instructions? The calibration process can be found in the manual. All the calibration-related settings can be accessed in F3.
5. How do we troubleshoot with the error codes? Go to the Error codes table in the manual. Please contact us if issues persist after following the manual diagnostics and instructions.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.